| HOME > IPC/JEDEC Dry Box storage Guideline |
|
| Dry Box Storage Guideline as Recommended by IPC/JEDEC J-STD 033C
|
|
(Handling, Packing, Shipping and Use of Moisture/Reflow Sensitive Mount Devices.)
According to IPC/JEDEC J-STD 033C IC packages should be stored in a dry box capable of maintaining either 10%RH or 5%RH in order to prevent components from absorbing moisture.
|
|
・Storage in a cabinet below 5%RH: No limit in floor life. |
|
 |
・Storage in a cabinet below 10%RH: Please see chart below for examples. |
|
(Section of Table 7-1 from IPC/JEDEC J-STD 033C) |
Package Type and
Body Thickness |
Moisture
Sensitivity
Level |
Floor life depending on humidity and temperature
|
Temperature |
| 5%RH |
10%RH |
20%RH |
30%RH |
40%RH |
50%RH |
60%RH |
70%RH |
80%RH |
90%RH |
Body Thickness > 3.1mm
including
PQFPs >84 pins,
PLCCs (square)
All MQFPs
or
All BGAs > 1mm |
2a |
∞
∞
∞
∞ |
∞
∞
∞
∞ |
94
124
167
231
|
44
60
78
103
|
32
41
53
69
|
26
33
42
57
|
16
28
36
47
|
7
10
14
19
|
5
7
10
13
|
4
6
8
10
|
←35ºC
←30ºC
←25ºC
←20ºC |
| 3 |
∞
∞
∞
∞ |
∞
∞
∞
∞ |
8
10
13
17
|
7
9
11
14
|
6
8
10
13
|
6
7
9
12
|
6
7
9
12 |
4
5
7
10
|
3
4
6
8
|
3
4
5
7 |
←35ºC
←30ºC
←25ºC
←20ºC |
| 4 |
∞
∞
∞
∞ |
3
5
6
8
|
3
4
5
7 |
3
4
5
7 |
2
4
5
7 |
2
3
5
7 |
2
3
4
6 |
2
3
3
5 |
1
2
3
4 |
1
2
3
4 |
←35ºC
←30ºC
←25ºC
←20ºC |
| 5 |
∞
∞
∞
∞ |
2
4
5
7 |
2
3
5
7 |
2
3
4
6 |
2
2
4
5 |
1
2
3
5 |
1
2
3
4 |
1
2
2
3 |
1
1
2
3 |
1
1
2
3 |
←35ºC
←30ºC
←25ºC
←20ºC |
| 5a |
∞
∞
∞
∞ |
1
2
3
5 |
1
1
2
4 |
1
1
2
3
|
1
1
2
3 |
1
1
2
3 |
1
1
2
2 |
1
1
1
2 |
1
1
1
2 |
1
1
1
2 |
←35ºC
←30ºC
←25ºC
←20ºC |
Under IPC-JEDEC-J-STD-033C, the floor life of IC packages that have been removed from their moisture barrier bags is reset using the benchmarks given below.
|
| Level |
Outside air conditions at exposure |
Reset humidity |
Floor life reset |
| 2 |
30°C 60% RH or below |
Storage cabinet with an internal humidity of 10% RH or less |
Where the exposure time is 12 hours or less, the time required for reset is 5 times the exposure time. |
| 2a |
| 3 |
| Level |
Outside air conditions at exposure |
Reset humidity |
Floor life reset |
| 4 |
30°C 60% RH or below |
Storage cabinet with an internal humidity of 5% RH or less |
Where the exposure time is 8 hours or less, the time required for reset is 10 times the exposure time. |
| 5 |
| 5a |
| Low-temperature low-humidity baking (example) IPC/JEDEC J-STD-033C
|
(The floor life can be reset at a temperature of 40°C and a humidity of 5% RH or less) |
| IC package thickness |
Level |
Baking humidity at 40℃ ≤5%RH |
Thickness ≤ 1.4 mm
|
|
Exposure time after floor life has elapsed > 72 hr |
Exposure time after floor life has elapsed ≤ 72 hr |
| 2 |
8 days |
5 days |
| 2a |
9 days |
7 days |
| 3 |
13 days |
9 days |
| 4 |
15 days |
9 days |
| 5 |
17 days |
10 days |
| 5a |
22 days |
10 days |
| Thickness >1.4 mm ≤ 7.0 mm |
2 |
25 days |
20 days |
| 2a |
29 days |
22 days |
| 3 |
37 days |
23 days |
| 4 |
47 days |
28 days |
| 5 |
57 days |
35 days |
| 5a |
79 days |
56 days |
Because IC packages with tape reels and LEDs cannot be baked at high temperatures, the values for low-temperature, low-humidity baking are set according to IPC/JEDEC (40°C, 5% RH). This is also ideal for baking other electronic components that cannot be baked at high temperatures. |
| Low-temperature, low-humidity baking according to IPC/JEDEC
|
Low-temperature, low-humidity baking according to IPC/JEDEC |
|
|
|
 |
|
| |
(C)2007 ERC Co.,Ltd. All rights reserved. |
|
|